Gaps between a window AC body and the window frame or side panels can be handled with foam strips or peel-off sealing materials. But the drain path under the unit and the air intake and exhaust vents on its sides and rear must never be blocked. Spray foam and silicone are hard to undo, so renters should not apply them. This article is for tenants who have gaps around a window AC and feel the cool air escaping, or find insects and dust coming in. It covers only methods that come off cleanly at move-out. For sealing the window and patching the wall after the AC is removed, see window AC hole waterproofing and repair. Removing the unit and moving it are outside the scope of this article.
Rental Window AC Gaps: Removable Fixes, No-Block Areas

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
First find where the gap is: around the body, side panels, and overlapping sashes
Gaps around a window AC are usually in three places: between the outer casing and the window frame, between the extension side panels on both sides (mostly plastic or acrylic) and the window frame, and where the sliding window sashes beside the AC overlap. Work out which kind of gap you have first, so you can choose the right material.
How to check: look for light by day, look for insects at night
- Daytime: Turn off the indoor lights and look for lines of light around the AC. The thickness of the light line roughly shows the width of the gap.
- Nighttime: With the indoor lights on and the outside darker, see which side of the window frame the small insects gather on. That is usually the path they use to get in.
- Take photos: Once you find a gap, photograph it first. The photos will be useful later when you talk to the landlord or move out.
Comparing four removable materials
The table below compares only materials that can be peeled off at move-out. The gap widths are general rules of thumb, and products vary a lot, so go by your own measurements and the product label.
| Material | Suitable gap width | Reversible? | Help against insects, dust, and rain |
|---|---|---|---|
| Foam strip or sponge strip | Medium to wide; thickness slightly greater than the gap width | Reversible; may leave a little adhesive residue | Good at keeping out insects and dust; gets heavy when wet, so limited protection against rain |
| Peel-off sealing strip | Narrow to medium gaps | Mostly peelable; test a piece first | Better at keeping out insects and dust; rain protection depends on whether it is water-resistant |
| Acrylic or plastic side panel plus tape | The joint between the side panel and the window frame | Reversible if low-tack tape is used | Seals only the joint; tape ages in sunlight |
| Brush strip | Narrow gaps where window sashes overlap | Reversible; mostly self-adhesive | More helpful against dust and insects; not suitable for large gaps |
Foam strips and sponge strips
Foam strip is the most common way to deal with the gap between the AC body and the window frame. Choose a strip slightly thicker than the gap and press it in along the gap, so it is lightly compressed and wedged in place. Take care not to cover the drain location under the unit or the heat-dissipation grilles. Foam on the outdoor side absorbs water and can grow mold, so seal mainly from the indoor side and check it regularly.
Peel-off sealing strips
These suit the thin gaps between the side panels and the window frame, and at window frame corners. Adhesiveness differs greatly between products, and some harden after sun exposure, so removing them may still leave marks. Stick a short piece in an inconspicuous spot, leave it for a few days, then peel it off to confirm it does not damage the frame surface before applying it over a large area.
Acrylic or plastic side panels plus tape
For the joint between a side panel and the window frame, you can apply low-tack, removable tape, or push a loose side panel back snugly into place. Do not use strong tape or double-sided foam tape, because removing them can easily take the surface of the window frame with them. A side panel that is broken or warped counts as equipment damage, so contact the landlord first and do not replace it yourself.
Brush strips for overlapping window sashes
The gap where sashes overlap is thin, but the window still has to open and close, so a brush strip suits it better than foam. Stick it to the side of one sash so the bristles lightly touch the other sash, with no need to jam it tight. It blocks dust and small insects, but do not expect it to be fully watertight.
Places you must not block
The principle is that gaps let in outside insects, dust, and wind, while holes and grilles let the AC drain and shed heat. Do not confuse the two.
| Location | OK to seal / Do not block | Notes |
|---|---|---|
| Gap between the outer casing and the window frame | OK to seal (foam strip) | Do not extend it downward to cover the drain path at the bottom |
| Gap between the extension side panels and the window frame | OK to seal (peel-off strip, low-tack tape) | If a side panel is damaged, contact the landlord |
| Gap where window sashes overlap | OK to seal (brush strip) | The window must still open and close |
| Drain hole and drain path at the bottom of the unit | Do not block | Water may pool or drip into the room |
| Heat-dissipation grilles and air intake and exhaust openings on the sides and rear | Do not block | Poor heat dissipation, so the AC stops cooling well |
Drain holes and drainage slope
Condensate drains outdoors along the unit's drain path as the manufacturer designed it, and the installation manual for some models specifies which way the unit must tilt. The angle and requirements differ by brand and model, so this article gives no figures. Follow the manufacturer's installation manual for your model, and do not prop up or adjust the unit yourself. When sealing gaps, never close off the bottom drain hole, drain channel, or the windowsill drain outlet with foam, tape, or silicone.
Heat-dissipation grilles on the sides and rear
The outdoor part of the unit needs airflow to shed heat, and there are usually intake and exhaust grilles on the sides and rear. The manufacturer's manual generally requires leaving ventilation space at these spots, with distances as stated in the manual. Covering the grilles with mesh or foam to keep insects out can disrupt the airflow. To keep insects out, just deal with the gap between the unit body and the window frame.
Symptoms after blocking: dripping indoors, not cooling
- Dripping into the room: When drainage is blocked, condensate may overflow from the unit. Take photos as evidence and see rental AC leaks: talking to the landlord and preserving evidence.
- Not cold, or alternating hot and cold: If the heat-dissipation grilles are blocked, the unit easily overheats.
- Remove the material you just added first: See whether the problem goes away, then check the filter for dust. For maintenance, see rental AC filter and evaporator cleaning.
Reasonable expectations for noise and rain leaks
Sealing gaps will not reduce the unit's own operating noise
Operating noise comes mainly from the compressor and fan, which are inside the unit, so sealing gaps cannot make it quieter. What sealing can improve is street noise and wind noise coming in through the gaps, but the effect depends on where the gaps are and on the window itself, and no specific figure can be promised. If the unit's own noise is the main problem, see this comparison of window and split air conditioners, and use the AC tonnage calculator to estimate the capacity the room needs.
For rain seepage, first tell whether it is the gap or the window frame
- If water drips only from the gap on one side and only when wind-driven rain slants in, it is most likely the gap, and you can first improve it with removable materials.
- If water seeps slowly out of the lower edge of the window frame, the windowsill, or the wall after it has rained for a while, it is most likely a problem with the frame's drain holes or the exterior wall. Sticking sealing material on yourself will only trap the water inside the frame.
- If you cannot tell, photograph the location and note the time, then notify the landlord. Do not apply caulk yourself.
Move-out removal and the line with the landlord's equipment
If the AC is equipment provided by the landlord, Article 432 of the Civil Code requires the tenant to look after the leased property with the care of a prudent manager, so avoid damaging the unit and the window frame when sealing. Article 429 provides that repairs to the leased property are borne by the lessor unless the contract provides otherwise or custom differs, so whether the landlord handles a damaged unit, a broken side panel, or a large gap that was already there depends on the contract and the actual situation. Article 430 provides that the tenant may set a reasonable period and demand repair, so it is best to leave a written or messaging record first.
At move-out, all the foam, strips, brush strips, and tape you applied must be peeled off completely and any adhesive residue cleaned up. The Ministry of the Interior's published Matters That Must and Must Not Be Agreed in Residential Rental Contracts has clauses on repairs and restoring the property to its original condition, so compare it with your lease before signing. The safest approach is to message the landlord beforehand that you will use only removable materials, get their consent, and take photos before and after the work.
Frequently asked questions
Can I fill the gap beside a window AC with spray foam?
Not recommended in a rental. Spray foam expands and sticks to the window frame, wall, and unit, making it very hard to remove completely, and the pressure can also warp the frame. Silicone is likewise hard to undo once cured. A full seal should be decided by the landlord, or done after the AC is removed, following window AC hole waterproofing and repair.
Do gaps around a window AC raise the electricity bill?
Gaps let hot outdoor air in, so the AC takes longer to hold the temperature and may use more power. How much more depends on the gap size, the weather, the room, and the model, and this article gives no energy-saving percentage. Keeping the filter clean and setting a sensible temperature are easier to control and have a more reliable effect.
Can I stuff something under a window AC to keep insects out?
Not recommended. There is a drain path under the unit, and stuffing in foam or other items may stop water from draining and cause pooling or dripping. First confirm where the insects come in, then deal with the gap between the unit and the window frame, or ask the landlord to assess the installation.
If the installation gap around a window AC is too big, is it the landlord's job to fix?
If the gap was there from the original installation, was not caused by the tenant, and affects use, you can usually raise it with the landlord first. If the contract provides otherwise, the contract governs. Keep photos and message records, and do not use spray foam or silicone without consent.
Sources
- Laws and Regulations Database of the Republic of China: Civil Code (checked 2026-11-11): Article 429 on the lessor's repair duty, Article 430 on demanding repair, Article 432 on the tenant's duty to look after the property.
- Energy Administration, Ministry of Economic Affairs: AC use and energy-saving materials (checked 2026-11-11): general guidance on AC filter maintenance and usage habits.



