Clamping a vernier caliper across external threads and measuring roughly 21 mm indicates a 4-fen (4分) class (G1/2 or similar taper thread), while roughly 26 mm indicates a 6-fen (6分) class (G3/4); ISO 228 basic major diameters are 20.955 mm and 26.441 mm respectively. A caliper measures only thread outer diameter and cannot distinguish parallel threads from tapered threads, which must be verified separately. "4 fen" and "6 fen" are colloquial trade designations; whether parts thread together securely depends on thread profile and pitch. Below is an overview of unit conversions, measurement locations, four hardware components, and a printable shopping checklist for hardware stores.
Faucet and Angle Valve Thread Sizing: G1/2 and G3/4 Guide

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
Distinguishing Three Dimensions: Fen, Millimeters, and Threads
Mixing up these three dimensional concepts frequently causes purchasing errors:
- Fen (分): Traditional fractional trade units used in plumbing, where 1 inch equals 8 fen (8). Thus 4 fen represents 4/8 inch (1/2 inch), and 6 fen represents 6/8 inch (3/4 inch). Trade explanations note that the vast majority of Taiwan residential faucets use 4-fen sizing (Changyong Plumbing, trade industry commentary).
- Millimeters (mm): Taiwan Water Corporation installation regulations stipulate that blueprint lengths and calibers must be expressed metrically under Article 43. Article 9 of the Water Supply User Water Equipment Standards requires faucet connection piping to be no smaller than 13 mm, and water meters no smaller than 13 mm (Article 10, per Taiwan Water Corporation guidelines). This 13 is a minimum nominal internal bore, not the external diameter measured on threads.
- Screw Threads: Faucets, flexible braided hoses, and angle valves seal based on thread profile (parallel or tapered), diameter, and thread pitch. This represents the critical specification.
Connecting 13 mm nominal caliber to 1/2-inch threads: Japanese manufacturer Takagi product guides state that their adapter connects to G1/2 parallel female threads marked as "call 13" for nominal bore 13; connecting to R1/2 tapered threads requires a separate adapter. While nominal caliber 13 aligns with G1/2 in faucet hardware, actual external thread diameter is distinct.
4-Fen and 6-Fen Thread Comparison Table
| Colloquial Term | Imperial Size | ISO 228 Thread Designation | Thread Major Diameter (mm) | Threads per Inch (TPI) |
|---|---|---|---|---|
| 2 fen (2分) | 1/4 inch | G 1/4 | 13.16 | 19 |
| 3 fen (3分) | 3/8 inch | G 3/8 | 16.66 | 19 |
| 4 fen (4分) | 1/2 inch | G 1/2 | 20.955 (rounded to 20.95) | 14 |
| 6 fen (6分) | 3/4 inch | G 3/4 | 26.441 (rounded to 26.44) | 14 |
| 8 fen (8分) | 1 inch | G 1 | 33.25 | 11 |
Thread specifications in this table reference the ISO 228 chart republished on Engineering ToolBox (where G1/2 and G3/4 list basic major diameters of 20.955 and 26.441 mm, rounded to 20.95 and 26.44). G indicates parallel pipe threads where joints are not made on threads. 1 inch equals 8 fen (1 inch = 25.4 mm).
- Specific CNS standard numbers and exact thread profiles used by Taiwanese plumbing manufacturers were not verified in official statutory data; refer to product labeling.
- External pipe diameters (such as PVC pipe OD) differ from thread major diameters and are not listed here.
- Online discussions referencing HVAC copper pipe sizing represent entirely different dimensions and must not be used for plumbing faucets.
Four Common Components and Thread Interfaces
| Component | Common Wall / Inlet Side | Outlet / Fixture Side | Key Notes |
|---|---|---|---|
| Angle valve | 4-fen male thread (R1/2 or G1/2) | 4-fen male thread (G1/2) | Wall joint uses thread seal tape; hose joint seals with internal rubber gasket |
| Braided water hose | 4-fen female nut (G1/2) | 4-fen female nut or quick-connect | Inspect internal rubber washer condition; avoid over-tightening |
| Basin / kitchen faucet | Braided hose inlet (G1/2) | Aerator nozzle | Check countertop mounting hole diameter and deck thickness |
| Wall-mount shower mixer | S-union offset legs into wall | Shower hose thread (G1/2) | Measure wall center-to-center distance between hot and cold outlets |
European fixtures may use metric threading; see our guide on imported sanitary fixture plumbing compatibility. Thermostatic valves require balanced pressure; see thermostatic shower valve water pressure requirements.
Hands-On Measurement: Six Practical Steps
- Shut off water supply: Close local angle valves or main water meters and open faucets to relieve line pressure. Do not force rusted valves.
- Take reference photos: Photograph existing plumbing before disassembly to verify orientation and parts.
- Remove the component: Disassemble only the piece being replaced while leaving adjoining fittings undisturbed.
- Measure external threads: Clamp caliper jaws across outermost thread ridges. Measuring roughly 21 mm corresponds to 4-fen (G1/2 or taper), and roughly 26 mm corresponds to 6-fen (G3/4 or taper), referencing ISO 228 major diameters. Calipers cannot distinguish parallel from tapered threads; verify via specifications or sample fitting.
- Count thread pitch: Count threads across 25.4 mm (1 inch): 14 threads indicate 4-fen or 6-fen; 19 threads indicate 2-fen or 3-fen; 11 threads indicate 8-fen. If female threads are difficult to measure, measure the mating male thread.
- Bring the old fitting to the store: Take the removed hose or fitting directly to hardware stores to test fit against inventory.
Takagi documentation notes metal threads may use thread sealant tape, though ISO 228 parallel joints seal via rubber washers rather than threads; check gaskets before wrapping excessive tape. If leaks persist at faucets, see quick repair for leaky faucets. Gas water heater connections must be handled by licensed technicians.
Pre-Purchase Checklist (Printable)
- ☐ Is the wall outlet female or male threaded, and what is its measured OD in mm?
- ☐ Are threads parallel or tapered? Bring the old part if uncertain.
- ☐ What are the inlet and outlet specifications of the angle valve?
- ☐ What are the hose nut sizes, length, and are there sharp bends?
- ☐ What are faucet inlet thread specs, and does an imported brand require metric adapters?
- ☐ Measured countertop hole diameter and deck mounting thickness.
- ☐ Took photos and recorded old fitting brand and model.
- ☐ Are older house angle valves corroded? Request plumbing repair rather than forcing.
To inspect comprehensive household plumbing, use our DIY home inspection checklist.
Providing these measurements to a plumbing technician saves return trips and material sourcing delays. Request itemized written quotes for valve replacements.
When to Call a Professional Plumber
- Angle valves or wall fittings are seized with rust and leak or fracture when turned.
- In-wall plumbing pipe locations require relocation or wall chiseling.
- Persistent leaks or wall and cabinet water staining occur after replacement.
- Any work involving gas water heater connections, which requires certified personnel.
Last updated: 2026-10-26
References
- Engineering ToolBox: ISO 228 Pipe Threads Table: supports G1/4 through G1 thread pitch and major diameter values (20.955 / 26.441 mm, rounded to 20.95 / 26.44) (in Chinese).
- Takagi: Half-Thread Connector Product Sheet: supports G1/2 parallel and R1/2 taper adapters and thread sealing tape guidelines (in Chinese).
- Taiwan Water Corporation User Water Equipment Application Guidelines (May 2022 / ROC year 111, month 5): metric unit mandates and minimum 13 mm pipe diameters (in Chinese).
- National Laws and Regulations Database: Water Supply User Equipment Standards Article 9: minimum 13 mm connecting pipe diameters for sanitary fixtures (in Chinese).
- Changyong Plumbing: Understanding Faucet Specifications: trade commentary on 1 inch = 8 fen, Taiwanese 4-fen prevalence, and metric imports (in Chinese).
Related reading: Faucet Aerator Cleaning: How to Unclog Spray Mesh · Angle Valve and Supply Hose Leaks: Replacement Guide · Kitchen Sink Drain Leaks Under Cabinets: Step-by-Step Fix · Sensor Faucet Repair: Solenoid Cleaning and Running Water · Taiwan Faucet Replacement Cost, DIY Steps, Lead-Free Marks