When faucet water flow suddenly slows down, sprays crookedly, or splatters in fine threads, the most common cause is sand and debris trapped inside the aerator mesh screen at the spout tip (termed aerator or flow straightener in HCG manuals, and aerator nozzle in TOTO manuals). Unscrew the aerator, brush away debris with a toothbrush under a running tap, and reassemble components in their original order. This is the standard maintenance procedure outlined in manufacturer manuals from HCG, TOTO, and Caesar, requiring no specialized tools or faucet body disassembly.
Faucet Aerator Cleaning: How to Unclog Spray Mesh

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
This article organizes maintenance instructions from HCG, TOTO, and Caesar, alongside Taipei Water Department guidance regarding turbid water and sediment following utility piping works, explaining how to disassemble, clean, avoid prohibited cleaners, and understand why household aerators clog.
Why Faucet Aerators Become Clogged
Aerators contain one or more fine mesh filter screens that mix air with water to create a soft, non-splashing stream while catching pipeline debris. Where does debris come from? The Taipei Water Department identifies several common scenarios:
- Nearby municipal water construction, pressure adjustments, or valve operations that stir up pipe scale, causing yellow or turbid water.
- Infrequently cleaned rooftop water tanks or cisterns where sediment settles and stirs up during refilling.
- Aging cast-iron supply pipes inside older buildings rusting, causing discolored yellow water when taps first open.
- Failure to shut the water meter stop valve and suction pump during water outages, creating negative pressure that draws dirt into private lines.
The Taipei Water Department recommends shutting pumps during outages and lowering inflow during reduced pressure; flushing rooftop tanks after water clears; and replacing corroded indoor plumbing. Running taps briefly to flush turbid water after service restoration prevents aerators from clogging. For steps before and after supply cuts, see our water outage preparation checklist.
HCG manuals highlight this in installation notices: "Open the water supply before installation to flush pipeline impurities." Failing to flush pipes often clogs brand-new faucets on day one.
Disassembly and Cleaning Steps: Following Official Manuals
- Unscrew the aerator. Caesar aerator gauge guides instruct unscrewing the aerator from the spout while maintaining a firm grip to prevent dropping. HCG manuals note that certain slotted aerators can be unscrewed by inserting a 10 dollar coin into the slot; TOTO thermostatic shower faucets include a dedicated removal key tool. If hand-turning fails, wrapping a protective cloth around jaws before applying pliers is recommended, though omitted from manuals.
- Note the sequence of parts. Aerators consist of an outer housing, mesh screens, and rubber washers. HCG notes washers must seat properly to prevent leaks; take a photo before disassembly. Clean shower heads similarly per our shower head vinegar descaling guide.
- Brush with a toothbrush under running water. HCG instructs brushing mesh screens lightly with a toothbrush under running water. Caesar specifies using an old toothbrush to brush away sand and scale; TOTO recommends brushing external mesh surfaces regularly.
- Never apply heavy pressure to mesh screens. The HCG BF3777 manual explicitly cautions: "Do not apply heavy pressure to the filter screen." Avoid pushing pins through plastic flow discs to preserve aerator performance.
- Reinstall and test flow. TOTO instructs placing the washer into the nozzle cap before reinstalling onto the spout and tightening by hand. Turn on the faucet to check for even flow without seam leaks. For stop valve issues, consult our faucet angle valve sizing guide.
Cleaning Agents and Tools to Avoid
| Item | Manufacturer Warning | Source |
|---|---|---|
| Routine Surface Cleaning | Wipe gently using a sponge or soft cloth with neutral detergent | HCG LF3311A, KF2217, and BF6237 manuals |
| Corrosive Cleaners, Scouring Pads, Abrasive Powders | Never use; damages electroplated finishes and shortens lifespan | HCG manuals |
| Acidic Cleaners, Chlorine Bleach, Alkaline Cleaners | May discolor finishes and damage synthetic resin components | TOTO thermostatic shower manuals |
| Nylon, Coir, or Hard Plastic Brushes and Abrasives | Causes surface scratches on chrome plating | TOTO manuals |
| Disassembling Faucet Body or Cartridge | Close inlet stop valves first; cartridges must be repaired by authorized technicians | HCG manuals |
Replacing a Damaged Aerator: Measure Threads First
If mesh screens crack, aerators can be replaced. In Taiwan, bathroom faucets commonly use female M22 or male M24 metric threads, with 22mm or 24mm outer diameters. For thread size conversions involving 4 fen (1/2 inch) and 6 fen (3/4 inch) fittings, see our guide. Measure thread diameter and determine whether threads sit on the aerator interior or exterior. Caesar provides dedicated sizing gauges for verification. Standard aerators cost around NT$50 to NT$100, while basic replacement faucets range between NT$500 and NT$600.
When to Seek Professional Assistance
- If aerators, shower filters, and angle stop valves are clean but water pressure remains low across all fixtures: troubleshoot rooftop water tanks, booster pumps, and main piping per our low water pressure troubleshooting guide.
- If the faucet body leaks, handles loosen, or taps fail to shut tightly: the ceramic cartridge has deteriorated; see our guide on repairing dripping leaky faucets.
- If water remains yellow, turbid, or odorous: the Taipei Water Department advises suspending drinking use, retaining water samples, and notifying the utility for assistance.
- For whole-faucet replacement or pipe modifications, record specifications and obtain quotes using the repair quotation generator.
Frequently Asked Questions
How often should faucet aerators be cleaned?
Every 3 to 6 months is recommended, or immediately following municipal pipe maintenance or supply restoration when water runs discolored.
What should I do if the aerator cannot be unscrewed by hand?
Wrap the aerator housing with a cloth or rubber band for grip, then turn counterclockwise with slip-joint pliers. Avoid bare metal tools that scratch chrome plating.
Why does a newly installed faucet have very low flow on its first day?
Plumbing debris or solder flux left in water pipes during installation commonly rushes forward to clog aerator screens instantly. Unscrew and rinse the aerator to restore normal flow.
Can pull-out kitchen faucets with water filters be disassembled this way?
Pull-out spray heads feature internal check valves and spray switches. Consult the manufacturer manual, as forcing them apart may break plastic internal clips.
Last updated: 2026-10-30
This article is compiled by SOSfix from official sanitaryware manuals and utility advisories for general reference; consult manufacturer technicians for repairs.
Sources
- HCG: LF3311A basin faucet manual (2018.05, document 600-90, verified 2026-11-04): Aerator cleaning, neutral detergent cleaning, and avoiding abrasive powders.
- HCG: KF2217 wall-mounted faucet manual (2018.05, verified 2026-11-04): Pre-installation flushing, slotted aerator removal with 10 dollar coin, and cartridge maintenance.
- HCG: BF3777 bath faucet manual (2023.07, document 3720M-90, verified 2026-11-04): Toothbrush cleaning, avoiding screen pressure, and neutral cleaning.
- HCG: BF6237 wall-mounted bath faucet manual (verified 2026-11-04): Aerator removal, toothbrush washing, and surface care.
- TOTO: Thermostatic shower faucet user manual PROD_MANU_20130722103948 (model TMN40STE, uploaded 2013-07, verified 2026-11-04): Regular aerator cleaning, avoiding nylon brushes, and dedicated tool removal.
- TOTO Taiwan: Faucet cleaning and maintenance FAQ (verified 2026-11-04): Faucet cleaning guidelines and finish protection.
- Caesar: Faucet aerator gauge guide and maintenance (published 2025-09-04, verified 2026-11-04): M22/M24 thread sizing, toothbrush cleaning, and scale removal.
- Taipei Water Department: Common consumer water quality questions (updated 111-07-14, verified 2026-11-04): Post-construction turbidity causes, rooftop tank cleaning, and pipe flushing.
- Ministry of Environment: Household cleaner safety guide (published 111-01-02, verified 2026-11-04): Safe handling of citric acid and household chemical cleaners.
Related reading: Stiff Faucet Handle and Squeaking Ceramic Cartridge Repair