When purchasing secondhand apartments or older condominiums, homeowners eager to design spacious open-plan living rooms or kitchen islands frequently plan to demolish interior partition walls. However, Taiwan sits on the Pacific Ring of Fire, where walls in older structures perform critical seismic functions; blindly knocking down load-bearing walls supporting vertical floor weight or reinforced concrete shear walls resisting earthquake lateral sway permanently damages building rigidity, triggering column blowouts and catastrophic soft-story collapses during tremors.
Load-Bearing Shear Wall Guide: Demolition Rules and Codes

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
Statutory Warning: Under Article 77-2 of the Building Act (第 77 條之 2) and Interior Decoration Regulations, altering partition walls affects structural safety; demolishing walls without architect permits from building authorities triggers fines of NT$60,000 to NT$300,000 (6 萬元以上 30 萬元以下罰鍰) and mandatory restoration; structural damage causing casualties incurs criminal liability under Article 193 of the Criminal Code (第 193 條)!
1. Four Structural Wall Types: Shear Walls, Bearing, Brick, and Drywall
Wall roles differ across construction eras and structural systems:
- Reinforced Concrete Shear Walls (RC Shear Wall): Wall thickness typically exceeds 20 cm (20 公分以上, with internal walls at 15 cm dual-grid rebar), cast with dense rebar cages and high-strength concrete. They resist lateral seismic shear and building sway; laws strictly prohibit demolition, coring penetrations, or thinning.
- Load-Bearing Walls: In vintage reinforced brick buildings or flat-plate slab systems, these walls bear vertical gravity loads from above floors; removal causes slab sagging cracks or collapse.
- Non-Bearing Brick Partition Walls: Common in walk-ups aged 30 to 40 years (30 至 40 年以上); wall thickness measures 12 cm (12 公分, single brick width); produces crisp tapping sounds; in older masonry buildings, brick walls share confinement strength and require structural engineer review before removal.
- Drywall / Wet Light Steel Partition Walls: Standard in modern condominiums; galvanized steel studs lined with gypsum, calcium silicate, or lightweight foamed mortar; thickness measures 8 to 10 cm (8 至 10 公分); hollow tapping sounds; non-structural and removable upon official filing.
2. Three Steps to Identify Structural Walls On-Site via Tools
Perform initial on-site diagnoses before retrieving original blueprints:
- Measure Total Wall Thickness: Measure wall depth at door or window jambs. Thickness over 20 cm (20 公分以上) indicates RC shear walls; thickness around 12 cm indicates standard brick walls; thickness around 8 to 10 cm with hollow resonance indicates light steel drywall.
- Inspect Alignment with Overhead RC Beams: Look upward: if a wall sits directly beneath a thick RC overhead girder and connects monolithically into columns, it represents a primary structural wall that must never be removed.
- Scan with Handheld Rebar Metal Detectors: Scan wall surfaces with electronic wall scanners. RC shear walls reveal dense cross-hatch rebar signals spaced 15 to 20 cm apart (15 至 20 公分); brick walls and wood drywall show zero rebar mesh grids.
3. Deciphering Building Bureau As-Built Structural Blueprints
The definitive verification requires retrieving original building permits and structural as-built drawings from local building authorities:
On Structural Floor Plans (S-Drawings, Structural Drawing):
- Solid thick black lines or hatched walls: Represent reinforced concrete structural shear walls labeled W1, W2, or SW (SW, W1, W2), strictly prohibited from alterations.
- Hollow double lines or "1B Brick Wall" (1B磚牆): Represent single brick partitions (labeled Brick Wall on architectural A-Drawings).
- Markings like "Drywall or LGS": Represent non-structural lightweight partitions.
4. Interior Wall Characteristics and Lawful Demolition Feasibility
| Wall Structural Type | Typical Thickness Standard | Tapping Acoustic Signature | Internal Rebar Distribution | Demolition and Coring Regulations |
|---|---|---|---|---|
| RC Exterior & Stairwell Shear Wall | 20 to 30+ cm (20-30 cm 以上) | Extremely dull, solid impact without resonance | Dual-layer dual-direction dense rebar mesh | Strictly prohibited from removal or coring |
| Internal RC Structural Shear Wall | 15 to 20 cm (15-20 cm) | Dense solid hard impact sound | Single or dual rebar grid layers | Prohibited from alteration; heavy fines |
| Old Reinforced Masonry Brick Wall | Approx. 12 to 24 cm (12-24 cm) | Slightly crisp solid brick resonance | No rebar; mortar-bound red bricks | Requires engineer verification of non-bearing status |
| Modern Dry / Wet Light Partition | 8 to 10 cm (8-10 cm) | Hollow resonant sound with metal resonance | Galvanized steel studs, zero rebar | Lawfully removable (Requires permit filing) |
5. Official Building Codes and Structural Review Standards
Interior wall alterations must conform to seismic design standards under the Building Technical Regulations Structural Chapter. Permit review protocols adhere to the Building Interior Decoration Management Regulations.
More remodeling guides: DIY Used House Inspection 10 Steps Guide, and Presale Floor Plan Customization and MEP Checklist.
6. Frequently Asked Questions
Q1: Is a wall over 15 cm thick 100% guaranteed to be an untouchable shear wall?
Over 80% are shear walls (80% 以上); some older walk-ups utilize 24 cm thick brick masonry (24 公分厚度紅磚) serving bearing functions; in modern condominiums, 15 cm RC walls contribute lateral stiffness, mandating blueprint verification.
Q2: Is cutting a small door or drilling an AC vent through an RC shear wall harmful?
Extremely harmful; shear walls rely on continuous rebar tension; cutting doors severs vertical main bars and ties, causing severe stress concentration that spawns diagonal X-cracks during earthquakes.
Q3: What liabilities arise from gutting ground-floor walls for commercial storefronts?
Gutting ground floors induces fatal soft-story collapses; unauthorized removal triggers heavy building bureau fines, orders to restore, criminal charges under Article 193 for building code violations, and civil lawsuits.
Q4: Does demolishing interior light steel drywall require interior decoration permits?
Yes; in buildings of 6 stories or higher, altering or adding partition walls mandates architect filings; unpermitted work reported by neighbors triggers fines from NT$60,000 to NT$300,000 (1, 2, 3, 4, 6, 8, 10, 12, 15, 20, 24, 30, 40, 77, 80, 193).