Looking for the Chinese version of this article?切換至繁體中文版 →

Gas Leak Emergency Steps: Smelling Gas and Hotline Guide

Gas Leak Emergency Steps: Smelling Gas and Hotline Guide

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.

This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.

When you smell gas, do not touch any electrical switches. First shut off gas valves, push windows open gently, and evacuate outdoors before dialing 119 or gas utility emergency hotlines. These actions represent the "Prohibit, Shut off, Push open, Evacuate" four-step protocol summarized by the National Fire Agency, Ministry of the Interior. Below is a quick-reference guide followed by official agency guidelines, utility hotlines across Taipei and New Taipei, and common dangerous errors.

Quick Reference: Four Steps During a Gas Leak

  1. Prohibit: Do not turn any electrical switches on or off. Do not touch lighting, range hoods, exhaust fans, or air conditioners to prevent generating electrical sparks.
  2. Shut off: Turn off gas valves. For liquefied petroleum gas (LPG) cylinders, close the cylinder valve knob; for piped natural gas, close the shutoff valve on the gas meter and valves on cooktops and water heaters.
  3. Push open: Gently push windows and doors open to allow gas to disperse naturally; do not fling windows open violently.
  4. Evacuate: Leave the building immediately for outdoor open air. Once outside, dial 119 or gas utility hotlines; in large leaks, dial 119 directly.
Safety Warning: If you cannot locate gas valves or windows cannot open, do not waste time inside: evacuate immediately and dial 119. This is the official guidance from the National Fire Agency reported by Taiwan FactCheck Center. Never use lighters or matches to search for leak locations; Shin Shin Natural Gas manuals explicitly prohibit open flames for leak detection.

Official guidance advises evacuating outdoors before calling for assistance; follow this sequence.

Three Official Agency Guidelines: Consistent Core Principles

Official procedures from three regulatory bodies emphasize identical safety priorities:

Agency SourceAction SequenceCritical Safety Alerts
National Fire Agency (NFA Disaster Prevention Portal)Prohibit electrical switching → Shut gas valves → Gently push open windows → Evacuate outdoors and dial 119In major gas leaks, dial 119 immediately
Energy Administration, Ministry of Economic AffairsClose appliance and service entrance valves → Slowly open doors and windows → Avoid electrical switches → Evacuate outside and notify gas utility or 119Avoid opening windows violently to prevent friction sparks; ban all open flames until leak stops
Great Taipei Gas Co., Ltd. (大台北區瓦斯)Open doors and windows → Close cooktop and valve taps → Shut meter and water heater valves, avoid electrical switches → Notify utilityNotifying the gas utility represents the final action step

All three guidelines share four core actions: avoid operating electrical switches, close gas valves, ventilate gently, and report from outdoors.

Should You Unplug the Refrigerator?

In response to fact-checking inquiries, the National Fire Agency stated that advice against opening refrigerators stems from concerns over compressor startup sparks; however, compressors cycle automatically regardless of whether doors are opened. Furthermore, do not intentionally unplug refrigerators, because pulling plugs can generate electrical sparks. Treat refrigerators like other electrical appliances: do not touch them.

Cylinder Gas vs Piped Natural Gas: Valves to Close

Gas System TypeValves to Shut OffStatutory Basis
LPG cylinder gas (桶裝瓦斯)Handwheel valve on cylinder top, plus appliance valves on stove and water heaterNational Fire Agency: close cylinder shutoff valves; for cylinder exchanges see LPG cylinder safety replacement guide
Piped natural gas (天然氣)Meter inlet shutoff cock (quarter-turn perpendicular to pipe), plus appliance cock valvesGreat Taipei Gas: shut gas meter shutoff cock and appliance valves

Know where your main gas meter shutoff cock is located before emergencies occur.

Gas Company Emergency Hotlines in Taipei and New Taipei

Check the company name and service phone printed on your gas bill:

Gas UtilityPrimary Service AreaEmergency Repair HotlineDaytime / SwitchboardHours
Great Taipei Gas (大台北區瓦斯)Taipei City (Songshan, Xinyi, Daan, Zhongshan, Zhongzheng, Datong, Wanhua)(02) 2767-6552 (02, 2767, 6552)(02) 2768-4999 ext 609 (2768, 4999, 609)24 hours (24)
Shin Shin Natural Gas (欣欣天然氣)New Taipei City (Yonghe, Zhonghe, Xindian, Shenkeng)(02) 2922-6666 (2922, 6666)(02) 2921-7811 ext 7276, 7277 (2921, 7811, 7276, 7277)24 hours (24)
Yangmingshan Gas (陽明山瓦斯)Taipei City (Shilin, Beitou)(02) 2895-9797 (2895, 9797)Verify telephone number on billCheck latest billing statement
Shin Tai Natural Gas (欣泰石油氣)New Taipei City (Sanchong, Xinzhuang, Banqiao)Refer to monthly gas billRefer to monthly gas billCheck latest billing statement
LPG Delivery StoreAll regions using LPG cylindersPhone number stamped on cylinder inspection cardStore landline numberCheck store business hours

Five Dangerous Mistakes During a Gas Leak

  • Turning on range hoods or exhaust fans: Energy Administration guidelines strictly prohibit turning on lights, fans, or range hoods. Ventilate solely by opening windows gently.
  • Using open flames or flicking lights to search for leaks: Leak detection must be performed by certified technicians using gas detectors or soapy water.
  • Assuming danger has passed when odor fades: Closing valves dissipates fumes, but physical leaks persist until professionally repaired.
  • Re-entering to retrieve mobile phones or valuables: If your phone is in hand, carry it outside; never re-enter a gas-filled building.
  • Confusing gas leaks with carbon monoxide: Fuel gases contain added mercaptan odorants; toxic carbon monoxide is colorless and odorless. If experiencing dizziness, nausea, or headaches, shut off appliances, open windows, evacuate outdoors, and dial 119. See our preventing carbon monoxide poisoning guide.

Post-Incident: When Can Appliances Be Safely Re-lit?

Do not restore gas valves until licensed utility technicians locate and repair the leak. Rubber hoses degrade over time; Shin Shin Natural Gas recommends replacing hoses immediately if cracked, aged, or bitten by pests. For post-earthquake inspections, review post-earthquake plumbing inspections. Piped gas renovations require utility approval under Taipei and New Taipei gas regulations. Include gas safety in our home inspection checklist, and troubleshoot burner faults in gas stove ignition and flame troubleshooting.

Calling 119 vs Gas Utility Emergency Hotlines

  • Call 119 directly: Heavy gas odor, someone collapsed or disoriented, inability to reach valves, stuck windows, or visible flames. If fire occurs, close valves if safe, extinguish small flames with damp towels or extinguishers, or evacuate and dial 119 immediately if fire cannot be controlled.
  • Call gas utility repair hotlines: You have evacuated outdoors, odor is mild, or a joint is suspected of minor leakage; call utility dispatch from outdoors.
  • When in doubt: Dial 119 from outdoors and allow fire dispatchers to coordinate emergency response.

Last updated: 2026-10-26

References