Auditing as-built mechanical, electrical, and plumbing (MEP) installations against approved presale customer customization drawings (客變圖說) represents a pivotal step during pre-handover walkthroughs to ensure concealed conduits reflect purchased configurations. During the rough-in customization phase, buyers frequently pay thousands for added 220V appliance circuits, upgraded Cat6 network drops, relocated water inlets, and recessed drainage runs. However, rushed construction schedules frequently lead subcontractors to revert to standard floor plans, leaving critical customizations missing behind drywall or buried under floor tiles.
Presale House Piping Diagram and Wiring Verification Guide

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
Importance of Presale Customization Drawings and On-Site Verification Prep
Prior to the walkthrough, buyers must assemble 4 fundamental construction documentation sets: the final architect-stamped electrical plan, sanitary plumbing schematic, weak current communications layout, and signed variation quotation sheets. Bring a 5-meter steel measuring tape, a laser distance meter, and colored adhesive markers to methodically cross-reference physical rough-ins against approved coordinates, preventing costly subsequent wall trenching.
Verifying Wall Receptacle Coordinates and Dedicated Circuit Configurations
Examine electrical outlets room by room to verify exact vertical and horizontal placement tolerances within 2 to 3 cm:
- Dedicated High-Power Circuits: Verify independent feeds for induction hobs (220V, 30A with 5.5 mm² wire), kitchen oven (220V, 20A), and microwave steam ovens. In the main panel, confirm each runs back to its own dedicated no-fuse breaker (無熔絲開關, NFB) rather than daisy-chaining with general 110V convenience receptacles.
- Height and Spacing Compliance: Kitchen counter outlets should sit 100 cm to 110 cm above finished floor level, while standard room outlets measure 30 cm to 45 cm. High-draw bathroom heater units require dedicated 20A circuits wired with 3.5 mm² conductors.
Weak Current Telecom Cabinet Audit: Cat6 Twisted Pair and Termination Quality
Modern smart home automation relies on high-speed low-voltage networking. Inspect twisted-pair cable jackets inside the media cabinet to confirm authentic Cat6 (23AWG) 250 MHz gigabit cabling rather than inferior Cat5e (24AWG) 100 MHz cable. Check that all 8 copper conductor cores are punch-down terminated properly onto patch modules according to T568B standards without excessive 13 mm (0.5 inch) untwisting. Test network continuity using a cable certifier to ensure zero cross-talk attenuation or impedance spikes.
Plumbing Rough-In Heights, Drainage Slope, and Wall Termination Standards
Verify cold and hot water rough-in elbows using a bubble level: cold on the right, hot on the left, separated by a standard 15 cm (±0.5 cm) center-to-center distance, exiting the wall at 90 cm to 105 cm finished height. Under-sink vanity drain connections must exit the wall at 45 cm to 50 cm height with a 1.5 inch (1.5") or 2.0 inch pipe diameter to maintain a gravity drainage slope of at least 1/100 (1%) towards the main vertical soil stack. Kitchen main waste lines require a 2.0-inch PVC pipe (outer diameter approx 60 mm) with an expansion joint sleeve through structural slabs.
Presale Customization Drawing Verification Points and Acceptance Matrix
| System Discipline | Engineering Drawing Item | Field Verification Method | Permissible Tolerance | Non-Conformance Remediation |
|---|---|---|---|---|
| Kitchen Power | 220V / 30A dedicated circuit | Multimeter phase-to-phase test | Voltage 220V ± 10%, dedicated NFB | Re-pull 5.5 mm² lines in existing conduit |
| Network Cabling | Cat6 Gigabit network drops | Read cable sheath printed text | Pure Cat6 23AWG 250MHz specification | Re-pull cable to media distribution box |
| Water Rough-Ins | Hot / cold stub separation | Tape measure & spirit level | 15 cm center distance, zero tilt | Adjust eccentric brass S-connectors |
| Appliance Plugs | Refrigerator & oven heights | Laser measure finished floor height | Deviation strictly < 30 mm | Trench plaster to reposition back-box |
Homeowners verifying presale installations can leverage our wire gauge ampacity and breaker matching calculator, cross-reference our interactive home inspection checklist calculator, and study our residential MEP renovation planning manual to protect investment value.
Frequently Asked Questions
If the builder installed Cat5e cable instead of specified Cat6, how should it be documented?
Annotate on the official punch list: "Weak current networking non-conformance: Drawing specifies Cat6 (23AWG) cable, field verification reveals Cat5e (24AWG) cable; contractor must re-pull specified Cat6 lines or provide agreed monetary compensation."
If 2 requested 220V circuits were omitted during rough-in, what compensation can be demanded?
Demand full refund of the original customization quotation fee plus secondary surface trenching and repiping expenses, typically amounting to NT$8,000 to NT$15,000 per missing circuit.
If hot and cold water pipes are reversed (cold left, hot right), will it disrupt daily usage?
Yes. Thermostatic shower mixers will fail to regulate temperature properly and may scald occupants, while single-handle faucets will operate counter-intuitively. The contractor must correct connection orientations before final sign-off.
Sources and References
Technical installation standards referenced from government regulatory publications:
- Ministry of Economic Affairs: User Electricity Device Installation Regulations
- Construction and Planning Agency, MOI: Building Technical Regulations MEP Chapter
Disclaimer: This technical guide is compiled from public engineering references and building standards. Actual on-site conditions vary across individual properties; readers should evaluate technical applicability carefully and consult qualified trade professionals.
Related reading: Bathroom Two-Speed Exhaust Fan Switch Wiring Guide · Taiwan Presale Change Request: Wiring and Plumbing Review