Required FE Forced Exhaust Principles and Fire Safety Regulations
In urban apartment buildings, many households install airtight aluminum windows on open balconies for rain, dust, or soundproofing. According to the National Fire Agency, Ministry of the Interior Fire Services Act Article 15-2 and the Gas Water Heater Installation Standards, in semi-enclosed or poorly ventilated spaces, it is strictly forbidden to install traditional natural exhaust (CF type) water heaters; you must install an FE forced exhaust gas water heater or an FF sealed forced intake/exhaust water heater.
FE forced exhaust water heaters feature a powerful DC fan at the top, performing a pre-purge before ignition to force combustion gases out through a metal pipe. If the exhaust pipe is installed incorrectly, it may trigger the pressure switch, causing the unit to stop, or lead to carbon monoxide accumulation, resulting in severe accidents.
⚠️ Safety Warning: CNS 13603 standards require that forced exhaust water heaters use heat-resistant, corrosion-resistant SUS 304 stainless steel pipes and elbows. Do not use aluminum foil or PVC pipes, as they can easily oxidize and crack, leaking deadly exhaust into the home.
Three Key Installation Factors: Slope, Resistance, and Length
Plumbers or gas technicians must strictly follow these three geometric and physical standards when installing exhaust pipes through walls or glass:
- Maintain a 2-degree downward slope toward the outside: Gas combustion produces water vapor (CH_4 + 2O_2
ightarrow CO_2 + 2H_2O). If the pipe is level or tilted inward, acidic condensate will flow back into the combustion chamber, corroding the ignition needle and heat exchanger.
- Equivalent length and elbow limits: The standard pipe diameter is Φ60mm. The total length is limited to 5 meters; each 90-degree elbow adds resistance equivalent to 1.5 meters of straight pipe. Do not exceed 3 elbows to prevent overheating.
- Exhaust outlet safety distance: The outlet must extend at least 10-15 cm beyond the wall or window, with no openable windows or air intakes within 60 cm to prevent exhaust from re-entering the home.
Fan Running but No Ignition? Pressure Switch Troubleshooting
If the fan runs but the unit displays an error code (such as E1 or E3) and fails to ignite, check the pressure switch:
- Pressure switch principle: The fan creates negative pressure in the Venturi Tube, which is transmitted via a transparent silicone tube to the diaphragm, signaling the motherboard to allow ignition.
- Silicone tube blockage: In winter, condensation can block the tube. Remove the tube, shake out the water, and blow it clear to restore function.
- Strong wind resistance: On high floors, strong winds can prevent the fan from overcoming external pressure. Install a stainless steel wind-resistant T-shaped or angled elbow at the outdoor outlet.
| Inspection Item |
Regulatory and Technical Standards |
Common Violations |
Consequences |
| Pipe Material |
SUS 304 Stainless Steel (thickness ≥ 0.3mm) |
Using thin aluminum foil hoses |
Corrosion and gas leakage |
| Installation Slope |
Downward slope of 1/50 (approx. 2 degrees) |
Level or inward slope |
Acidic condensate corrosion |
| Joint Sealing |
O-ring silicone seal + locking ring |
Electrical tape or no sealant |
Pipe detachment due to vibration |
Stainless Steel Pipe Modification and Professional Quotes
Per fire regulations, installation must be performed by a certified gas appliance technician who attaches a registration label:
- Exhaust pipe extension costs: Standard units include a 50cm pipe and one 90-degree elbow. For larger balconies, purchasing a SUS 304 Φ60mm extension (50cm) costs about 250-400 NTD, a 90-degree elbow costs 300-450 NTD, and a glass hole cover costs 150 NTD.
- Labor for glass drilling and pipe modification: If drilling through reinforced glass (recommended diameter Φ65-70mm), the total labor and material cost is approximately 1,500-2,500 NTD.
If you experience low water pressure, refer to the Water Heater Ignition Troubleshooting Guide and Gas Water Heater No Hot Water Analysis.
Forced Exhaust Water Heater FAQ
Q1: Is there a fire risk if the exhaust pipe feels warm near wooden ceilings?
Exhaust gas temperatures are around 90°C-140°C. While below the ignition point of wood, the pipe must not touch flammable materials. Regulations require at least 15 cm of clearance, or the use of double-layered stainless steel insulation sleeves when passing through walls.
Q2: Can I use standard silicone to seal exhaust pipe joints?
Standard silicone is only heat-resistant up to 90°C-120°C and will degrade. Use factory-provided high-temperature rubber seals or specialized high-temperature neutral silicone (rated up to 300°C) to ensure a secure, leak-proof seal.