Looking for the Chinese version of this article?切換至繁體中文版 →

Understanding Air Purifier CADR and Room Size Conversion

Understanding Air Purifier CADR and Room Size Conversion

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.

This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.

The U.S. Environmental Protection Agency (EPA) estimation table suggests: for every 100 square feet (approx. 2.8 ping (1 ping ≈ 3.3 m²)), at least 65 cfm of CADR is required, assuming an 8-foot ceiling; this article converts this to approximately 0.65 cmm per ping (approx. 39 cubic meters/hour). Taiwan's energy efficiency labeling uses CASR (unit cmm); when purchasing, check CASR, energy efficiency ratings, and filters, while avoiding models that intentionally generate ozone.

Reminder: The U.S. EPA explicitly advises against using air purifiers that intentionally generate ozone, as ozone irritates the lungs; electrostatic precipitators, ionizers, improperly coated UV lamps, and plasma-type models may also release ozone. Purifiers cannot replace opening windows for ventilation or removing pollution sources, nor can they solve the root cause of mold. Taiwan's inspection and labeling regulations are subject to the latest announcements by the Bureau of Standards, Metrology and Inspection (BSMI) and the Energy Administration, Ministry of Economic Affairs.

CADR and CASR: Two Names, Two Units

CADR (Clean Air Delivery Rate) is a common metric in the U.S. The EPA explains: the higher the CADR, the more particles it can filter and the larger the area it can serve, usually measured at the highest fan speed; some packaging lists separate CADR for smoke, dust, and pollen, representing small, medium, and large particles. To filter fine particles like PM2.5, look at the "smoke" CADR. The EPA also notes that CADR only targets particles, as there is no widely used rating system for gases.

Taiwan's regulations are different. The Ministry of Economic Affairs announced on June 11, 2021, the "Regulations Governing Energy Efficiency Labeling and Inspection for Air Purifiers," effective January 1, 2023 (partially amended on May 27, 2025). According to this announcement:

  • It applies to air purifiers compliant with CNS 16098, measuring the Clean Air Supply Rate (CASR) in cmm (cubic meters per minute).
  • Energy efficiency = CASR ÷ operating power (W), unit cmm/W; measured values must be at least 95% of the labeled value.
  • Models with a CASR lower than 0.26 or higher than 12.80, as well as those using only ozone, UV, or photocatalysts for purification, are not covered by this grading announcement.

Whether the test methods for CASR and CADR are identical is unconfirmed as this article has not read the original CNS 16098 text. Units can be converted: 1 cfm is approx. 0.0283 cmm, and 1 cmm = 60 cubic meters/hour. When comparing foreign models, convert units to be consistent first.

How to Calculate Applicable Ping

This article did not find an official Taiwanese formula for "applicable ping"; the "applicable ○ ping" written on packaging is labeled by manufacturers, and calculation methods vary. Official figures to reference are the U.S. EPA estimation table (8-foot ceiling, approx. 2.44 meters): 100, 200, 300, 400, 500, 600 square feet require minimum CADR of 65, 130, 195, 260, 325, 390 cfm respectively, which is 0.65 cfm per square foot.

Article conversion: 0.65 cfm ÷ 0.0929 square meters × 0.0283 cmm ≈ 0.198 cmm per square meter; multiplied by 3.3058 square meters per ping, it is approx. 0.65 cmm per ping, converted to approx. 39 cubic meters per hour. The table below shows the minimum requirements based on the EPA estimation table, not official Taiwanese standards or official CASR thresholds; use it only as a rough estimate when comparing with CASR on packaging:

Room PingArticle Converted Min. Clean Air (cmm, from EPA CADR)Approx. (cubic meters/hour)Approx. (cfm)
3 ping2.011869
5 ping3.3197116
8 ping5.2314185
10 ping6.5393231
15 ping9.8589347

The EPA reminds that if the ceiling is higher than 8 feet, choose a larger unit. Taipei and New Taipei apartments often have 2.8 to 3 meter ceilings; this article suggests scaling up proportionally, e.g., 3 meter ceiling multiplied by 3 ÷ 2.44 ≈ 1.23. Open-plan living and dining rooms should be calculated as one space; if the area exceeds a single unit's capacity, the EPA suggests using multiple units.

Energy Efficiency Rating and Standby Power

The grading threshold for air purifiers (Appendix 5) has only one table, regardless of capacity:

RatingEnergy Efficiency CASR/W (cmm/W)Standby Power Limit
Level 10.169 or higherWithout wireless connectivity 1.00 W or less; with wireless connectivity 2.00 W or less
Level 20.141 or higher, lower than 0.169Same as above
Level 30.113 or higher, lower than 0.141Same as above
Level 40.085 or higher, lower than 0.113Same as above
Level 50.057 or higher, lower than 0.085Same as above

Article trial calculation: A machine with CASR 5.0 cmm needs an operating power of approx. 29.6 W or less to reach Level 1 (5.0 ÷ 0.169). Purifiers are often left on all day; standby and operating power are reflected in electricity bills; for how to estimate total standby power, see standby power annual cost. The Energy Administration, Ministry of Economic Affairs further explains that cleaning filters every 2 to 3 weeks can save about 5% of electricity annually, but check the manual before cleaning to confirm if the filter can be washed by the user.

Filter Rating: What HEPA Means

The EPA cites the U.S. Department of Energy definition: HEPA filters can theoretically filter at least 99.97% of particles 0.3 microns in size; 0.3 microns is the most penetrating particle size, and particles larger or smaller are captured with higher efficiency. The EPA also explains that portable purifiers mostly rely on HEPA filters to achieve high CADR.

  • Gases and Odors: Choose models with activated carbon or other adsorption filters; the more material (the thicker), the better the effect; the EPA states that technologies like plasma, photocatalysts, and UV have not been proven effective for removing gases in home units. For formaldehyde standards and testing in new renovations, see new renovation formaldehyde levels.
  • Replacement: The EPA points out that all filters must be replaced regularly; they become ineffective if too dirty or overloaded. Replacement cycles depend on the manufacturer's manual.
  • Noise: The EPA gives an example that 50 decibels is about the sound of a modern refrigerator running; for bedrooms, refer to the labeled noise value.

Ozone Risk: Which Models to Be Careful With

The EPA's "Ozone Generators that are Sold as Air Cleaners" explanation: No federal agency in the U.S. has approved such devices for use in occupied spaces; ozone inhalation can damage the lungs, and even lower concentrations may cause chest pain, coughing, shortness of breath, and throat irritation, and may worsen asthma. The EPA also points out that at concentrations not exceeding public health standards, ozone is not effective at removing many chemicals that cause odors, and ozone does not remove particles like dust or pollen.

In Taiwan, the regulations found by this article are as follows, please note the scope of application:

RegulationContentScope of Application
Indoor Air Quality StandardsOzone (O3) 8-hour value 0.06 ppm; PM2.5 24-hour value 35 μg/m³Per Articles 6 and 7 of the Indoor Air Quality Management Act, applies to announced public places (schools, medical institutions, stations, etc.), does not directly regulate general homes
BSMI Mandatory Inspection Air Purifying AppliancesPrinciples include filter, electrostatic, ionizer, ozone, UV, or photocatalyst, rated voltage 250V or less, inspected per CNS 60335-1, CNS 60335-2-65, etc.This is a safety and electromagnetic compatibility inspection; this article has not read the original CNS 60335-2-65 text regarding ozone limits
Energy Efficiency Grading AnnouncementModels using only ozone, UV, or photocatalysts are not subject to gradingThis only means they are not included in energy grading, not that they are safe or effective

This article suggests: check the purification principle before buying; do not use models marketed for "ozone sterilization" or "active oxygen" in rooms with people; for those with ionizer, electrostatic, or UV functions, check the manual for ozone-related information, and turn them off if possible. For whether to close windows when outdoor air quality is poor, see AQI levels for closing windows.

Common Questions

How big should an air purifier be for an 8 ping room?

According to this article's conversion from the U.S. EPA CADR estimation table, it requires a clean air volume of at least 5.2 cmm (approx. 314 cubic meters/hour, 185 cfm), and scale up for higher ceilings. This is the article's converted value, not an official Taiwanese figure; Taiwan has no official ping formula, and this article cannot confirm if the test methods for CASR and CADR are the same, so use it only as a reference when comparing CASR.

Can a HEPA filter remove formaldehyde and odors?

No. HEPA is for filtering particles; formaldehyde and odors are gases, which require adsorption filters like activated carbon, and the EPA also states that there is currently no widely used rating system for gases. When the source is new furniture or building materials, ventilation and reducing pollution sources are more fundamental.

Are ionizer air purifiers safe?

The EPA points out that ionizers, electrostatic precipitators, and some UV and plasma models may release ozone, and advises avoiding models that intentionally generate ozone. Please check the purification principle and manual before purchasing.

Do air purifiers need to be on 24 hours a day?

The EPA explains that the higher the fan speed and the longer the operation time, the more air is filtered. This article suggests keeping it on continuously in rooms you stay in often, and lowering the fan speed when no one is present; electricity costs can be estimated using operating power and energy efficiency ratings.

Last updated: 2026-10-31

This article was compiled by SOSfix using public information and is for general reference only; for specific cases, please contact the Bureau of Standards, Metrology and Inspection (BSMI), the Energy Administration, Ministry of Economic Affairs, or the air purifier manufacturer.

Data Sources