For rooftop 透天厝, 老公寓或社區頂樓的水塔, the most common water resource waste disaster is overflow (水塔進水滿溢), where tap water continuously flows down the rooftop overflow pipe 24 hours a day to the drainage ditch, until receiving a water bill skyrocketing by thousands of dollars makes one realize something is terribly wrong. The root cause of the tank overflow is that the internal rubber valve plug of the float valve (進水浮球凡而), which is responsible for automatically cutting off the water inlet inside the 水塔, has hardened and leaked, or the float itself is damaged, seeped, and sank, losing its buoyancy lever closing mechanism.
Fixing a Leaking Rooftop Water Tank Float Valve

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
Warning: When climbing to the rooftop for 水塔 maintenance, be sure to pay attention to fall prevention safety. Climbing aluminum ladders in strong winds or heavy rains is strictly prohibited. Before construction, you must first close the main tap water inlet valve in front of the 水塔 (or turn off the booster pump power). Forcibly unscrewing the float valve body under full water and high-pressure conditions is strictly prohibited to avoid falling accidents caused by high-pressure tap water instantly spraying out.
1. Working Principle and Torque Balance Mechanism of Mechanical Float Valves
Automatic water replenishment in traditional stainless steel 水塔 mostly adopts pure mechanical float valves. When household water consumption causes the water level in the 水塔 to drop, the hollow metal or plastic float sinks with the water surface, and through a long brass/stainless steel connecting rod (lever principle), pulls the piston pin inside the valve body outward, allowing tap water to immediately flow into the 水塔 at a high volume.
When the water level rises to the preset height, the float rises due to Archimedes' buoyancy in water, driving the connecting rod shaft to generate a strong leverage thrust, pinning an internal pressure-resistant water-stopping rubber plug (EPDM rubber gasket) tightly against the inlet nozzle. At this time, the buoyancy torque must be greater than the water supply pressure of the tap water pipe network (usually 1.5 to 3.0 kg/cm²), so that the water inlet can be completely cut off without a single drop leaking.
2. Four Core Failure Analyses of Unceasing 水塔 Overflow
- Rubber water-stopping gasket aged, sunken, or hardened with trapped sediment: Fine quartz sand particles carried by the tap water get stuck between the rubber gasket and the copper nozzle sealing surface, forming grooves due to long-term erosion; or the rubber gasket has lost its elasticity due to years of pressure, and tap water continues to seep through tiny gaps, eventually causing the 水塔 to overflow.
- Metal or plastic float broken and seeping, losing buoyancy and sinking: The weld seam of the stainless steel float is corroded by chlorine to produce pinholes, or the plastic float becomes brittle and cracked from sun exposure, and after filling with water internally, its weight multiplies, preventing the float from ever rising again, leaving the inlet valve permanently in a 100% fully open state.
- Lever copper rod pivot pin rusted and stuck: The float valve pivot pin has grown green patina or scale on its surface due to the high-humidity environment at the top of the 水塔 for many years, causing excessive friction on the pivot so it cannot swing freely, getting stuck in a half-open position.
- Tap water network pressure too high at night, breaking through valve sealing limits: In some areas, tap water pressure during off-peak hours at night reaches 4.0 kg/cm² or higher. If the float valve specification is too small or the lever torque arm is too short, the buoyancy is insufficient to resist the ultra-high water pressure, causing no leaks during the day but crazy leaking at midnight.
3. 3-Minute Emergency Inspection: Confirming Float Damage or High Water Level
- Open the cover and manually lift the float rod: Climb to the top of the 水塔, open the manhole cover, and gently lift the metal rod of the float upward to a horizontal position by hand. If the water flow at the inlet can be completely stopped immediately at this time, it means the valve body sealing function is intact, and it is merely a "water level adjustment set too high" or "copper rod angle too straight". You only need to bend the copper rod downward for a minor adjustment.
- If lifting with all your might still results in continuous spraying: If the connecting rod has already been pushed to the limit by hand and locked, and the outlet still sprays water continuously with a sizzling sound, it is confirmed that the internal water-stopping rubber gasket is cracked and worn, or the edge of the copper nozzle has been cut into deep grooves by scale. You must replace the rubber plug or the entire float valve assembly.
- Shake the float body and listen for sound: Remove the round float and shake it. If a splashing water sound comes from inside and the feel is heavy, it is confirmed that water has seeped inside the float, and the float must be replaced with a new one.
4. 5 Steps to DIY Replace Thickened All-Copper Inlet Float Valve
- Close the water inlet source and lower the water level: Close the 3/4-inch or 1-inch tap water control valve in front of the 水塔, open the sewage drain valve at the bottom of the 水塔 or let household taps consume part of the water volume so that the water surface is lower than the inlet pipe opening by at least 15 cm, clearing space for hands to work.
- Unscrew the old float valve body counterclockwise: Use two pipe wrenches (one to fix the iron inlet pipe on the outer wall of the 水塔 to prevent pipe twisting and bursting, and the other to grip the old valve body itself), and forcefully unscrew the damaged old float valve assembly counterclockwise.
- Thoroughly clean the external metal female threaded pipe opening: Use a wire brush to remove old raw material tape debris and rust on the threads of the inlet connector on the inner wall of the 水塔, and wipe it clean with a dry cloth.
- Correctly wrap thread seal tape and tighten for airtightness: Take a brand new all-copper float valve (it is recommended to specify the 3/4-inch or 1-inch thickened high-pressure resistant specification). Tightly wrap "thread seal tape (PTFE tape) 18 to 22 turns" clockwise around the external metal threads. Screw it into the pipe opening clockwise by hand, and finally tighten it with a pipe wrench until it feels heavy and positioned, ensuring that the connecting rod swing pivot faces vertically straight down.
- Fine-tune connecting rod bending angle to set safe water level: Screw on the brand new stainless steel float. Hold the middle section of the brass connecting rod with both hands, and bend it downward slightly with force by about 15 degrees so that the float reaches the closing position earlier. Turn on the water inlet valve for a practical test to ensure that when the water level rises to at least 5 to 8 cm below the "水塔 overflow pipe opening", the water inlet is completely cut off and stopped, retaining a sufficient wave safety margin.
5. Mechanical Float Valve vs. Electrode Water Level Controller Comparison Table
| Water Level Control Method | Target Audience | Advantages | Disadvantages and Risks | Replacement Cost (TWD) |
|---|---|---|---|---|
| Thickened All-Copper Float Valve (Recommended) | 水塔 supplied by natural tap water pressure | Purely mechanical, completely electricity-free, extremely simple and durable structure | Float requires regular inspection to prevent cracking | $450 - $800 |
| Stainless Steel Radar Liquid Level Switch | Needs to link to the first-floor water pumping motor | Adjustable upper and lower water level difference with dual floats, protects motor | Switch micro-action contacts easily oxidize and mold in long-term moisture | $800 - $1,500 |
| Electronic Electrode Rod Liquid Level Controller | Basement cisterns in buildings and rooftop 水塔 | Sensitive sensing, no mechanical wear, fully automatic linkage | Electrode rods need protection against lightning surges and scale crystallization short circuits | $2,500 - $4,500 |
6. Official Inspection Standards and Tap Water Supply Equipment Specifications
Rooftop cisterns and 水塔 water inlet control hardware in buildings shall comply with the Bureau of Standards, Metrology and Inspection (BSMI) CNS 4800 "Stainless Steel Water Storage Tanks" and Article 14 of the Taiwan Water Corporation "Standards for User Water Supply Equipment" (the bottom end of the 水塔 water inlet pipe must be at least 5 cm higher than the upper edge of the overflow pipe, and forming an inverted siphon to pollute public tap water trunk lines is strictly prohibited).
Further reading references: How to Check for High Water Bill Hidden Leaks? Water Meter Idling Test, Progressive Tariff, and Internal Underground Leak Reductions, and Apartment 水塔 Regular Cleaning and Maintenance: White Iron 水塔 Turbid Output, Float Valve Fault Overflow Repair Guidelines.
7. Frequently Asked Questions (FAQ)
Q1: The 水塔 float valve was just replaced with a new one. Why is there still a tiny bit of dripping water that won't stop when full?
This is usually caused by tiny iron chips or sediment particles flaking off the pipe walls when the tap water supply is restored, directly getting stuck on the rubber sealing surface of the new valve body. At this time, you only need to manually pull the float connecting rod up and down rapidly a few times, using the large water flow to wash away the sand particles stuck on the rubber gasket, and 100% sealing can be restored.
Q2: Is it better to buy a plastic float or a stainless steel float?
It is strongly recommended to purchase the "304 stainless steel thickened float"! In summer, the interior of a rooftop 水塔 in Taiwan resembles a stifling kiln, with temperatures soaring above 50°C to 60°C. In a high-temperature steam and chlorine environment, plastic floats will become brittle and crack, letting in water within 2 years. Although stainless steel floats cost a hundred NT dollars more, their service life can last for more than 10 years.
Q3: Must the 水塔 overflow pipe be equipped with an insect-proof net?
It is absolutely necessary to install one! If the overflow pipe is not equipped with a stainless steel fine-mesh insect-proof net at the end, geckos, cockroaches, mice, or even birds can easily crawl into the 水塔 along the overflow pipe, drown, and rot, causing the tap water of the entire building to be seriously contaminated by pathogens. The standard practice is to slip a corrosion-resistant metal gauze net onto the overflow pipe outlet and lock it with a pipe clamp.
Q4: When replacing the float valve, what should I do if the water pipe is twisted and broken on the iron pipe fitting of the 水塔?
This often happens on old galvanized iron pipes. When applying force to disassemble, "you must use dual pipe wrenches to clamp and balance the force in opposite directions". Never pull fiercely with a single pipe wrench in one hand! If the pipe wall is thin and severely rusted, it is recommended to have a 水電師傅 (plumber/electrician) completely convert the rusted iron pipes around the outer perimeter of the 水塔 into 304 stainless steel press-fit pipes or thickened Nanya PVC pipes all at once, ensuring complete safety.