The "X-shaped tape" that is stuck every year during the typhoon season is actually wrong
Whenever a typhoon warning is issued, many families in Taipei and New Taipei will dig out paper tape or kraft tape and paste "X", "meter" or even "well" shapes on the window glass, believing that this can prevent the glass from breaking. This practice has been popular in Taiwan for decades and has almost become a Taiwan defense ritual. However, the results of rigorous tests conducted by the Architectural Research Institute of the Ministry of the Interior in a wind tunnel laboratory surprised many people - Glass with tape on it is more likely to break than glass without tape.
The reason is the so-called "stress concentration effect" in physics. When the tape is adhered to the surface of the glass, it will change the way the force is distributed when the glass is subjected to wind pressure. When wind pressure acts on the entire piece of glass, the stress that should be evenly distributed is concentrated at the junction of the edge of the tape and the glass frame due to the constraints of the tape, forming a structural weakness. The result is that at the same wind speed, the tape-covered glass reaches the breakage threshold faster than the bare glass.
Is the tape completely useless? The only effect is to "reduce scattering"
Strictly speaking, tape has one function: When the glass has broken, tape can reduce the chance of the fragments flying around and injuring people. But it is completely useless to prevent the glass from being blown by strong winds. In other words, if your purpose is to prevent windows from being broken during a typhoon, applying tape is not only a waste of time, but may also be counterproductive.
Many masters engaged in plumbing, door and window installation in Shuangbei said that in the window repair cases received after the typhoon, many of the glass with tape on it was still broken, and the homeowners had to spend more time to remove the residual glue and debris.
A truly effective anti-typhoon glass solution
Instead of spending time on applying tape, it is better to fundamentally improve the wind resistance of the windows. The following are three mainstream practices currently recognized by Taiwan’s building doors and windows industry:
- Laminated Safety Glass: This type of glass has a layer of PVB or SGP adhesive film sandwiched between two layers of glass. Even if it is broken by external force, the fragments will stick firmly to the film and will not break into sharp, razor-shaped fragments like ordinary glass. It is currently recognized as the most suitable glass choice for typhoon protection, and has been adopted in many windward windows of new buildings.
- Tempered Glass: After being heated at high temperatures and then rapidly cooled, the strength is about 4 to 5 times that of ordinary glass. When broken, it will break into smaller round granular fragments, which are less likely to cause serious cuts. Be aware, however, that tempered glass cannot be cut on site and must be pre-cut to the correct size at the factory.
- Safety Film: If you do not want to replace the entire glass, you can affix a professional explosion-proof film on the inside of the existing glass. The effect is similar to the principle of glued glass, which can stick the fragments together when broken. Quality varies greatly on the market, so it is recommended to purchase products that are thicker than 4mil (approximately 0.1mm) and pass ANSI Z97.1 or EN 12600 safety test standards.
Window frame hardware is the invisible key to preventing typhoons
Many people only care about whether the glass will break, but ignore the problem of the window frame itself. In the Taipei Basin and New Taipei coastal areas, typhoons bring not only strong winds, but also large amounts of entrained horizontal heavy rain. If the airtightness and watertightness of the window frame are insufficient, rainwater will pour into the room through the gaps in the window frame, even if the glass is intact.
The following inspections are recommended before the typhoon season:
- Window sash tightness: After closing the window, run your fingers around the edge of the window frame. If you can clearly feel air leakage, it means that the airtight strip has aged, hardened, deformed, and needs to be replaced.
- Hinges and Pulleys: If the pulleys on a sliding window are stuck or skewed, the sash will not close completely. If the hinges of the sliding windows are loose, strong winds may directly blow the sash open or even blow it off.
- Silicon Caulking: If the silicone between the window frame and the wall has cracked, fallen off, or turned moldy and black, it will lose its sealing effect. Re-silicon is the most common and most economical way to prevent leaks.
The wind pressure resistance of different grades of aluminum windows is very different
According to CNS 11527 standard, the wind pressure resistance rating of Taiwanese aluminum windows ranges from 360S to 500S. The 360S level can withstand wind pressures approximately equal to level 10 winds, while the 500S level can withstand wind pressures above level 17. For general residences in the greater Taipei area, it is recommended to use at least 360S grade aluminum windows; if your home is on a high floor (above the tenth floor) or is located on the windward side, it is strongly recommended to upgrade to 440S or even 500S grade.
| Typhoon prevention measures | Effect description | Estimated cost (NTD) |
|---|---|---|
| Replacement of laminated safety glass (per day) | Wind pressure resistance + no scattering when broken, first choice for typhoon prevention | NT$ 350 – $600/person |
| An explosion-proof film is attached to the inside of the glass | An economical solution without replacing the glass to reduce the scattering of debris | NT$ 150 – $350/person |
| Comprehensive replacement of airtight tape | Restore the tightness of the window frame to prevent wind and rain from penetrating | NT$ 3,000 – $8,000/window |
| Window frame silicone re-caulking | Seal the joints between windows and walls to prevent lateral rainwater from penetrating | NT$ 1,500 – $3,500/window |
Conclusion: Put down the tape and do the right thing
The habit of putting tape on windows during typhoons is like many people’s belief that they should take vitamin C when they have a cold. It sounds reasonable, but the actual effect is limited or even counterproductive. What can truly protect you and your family is to choose the right glass material, maintain the window frame hardware, and keep the silicone caulking intact. Doing these things before the typhoon comes is the most pragmatic investment in typhoon prevention.
The Ministry of Economic Affairs' latest "Regulations on Consumer Electrical Equipment Installation" and the key points of electricity safety in old houses
Due to the popularity of high-power household appliances (such as air fryers, microwave ovens, dishwashers, instantaneous electric water heaters, and IH furnaces) in recent years, the Energy Administration of the Ministry of Economic Affairs has revised the "Regulations on Consumer Electrical Equipment Installation" many times to strictly require the diversion and protection mechanisms of residential electricity circuits. Statistics show that more than 30% of building fires in Taiwan are caused by electrical factors, among which "old wire insulation deteriorates and short circuits", "socket contacts are oxidized and loose, poor contact" and "non-fuse switch (NFB) overloaded and failed to trip" are the three main fatal causes.
Old apartments in Shuangbei that are more than 30 years old have a total original designed power capacity of only 30A to 40A, and several rooms often share the same 1.6mm or 2.0mm circuit. In the modern standard safety configuration, kitchen electrical cabinets, bathroom equipment, and air-conditioning and heating machines must all be equipped with 5.5mm² dedicated circuits (single circuit and single socket). It is recommended that the main switch box be upgraded to a busbar (Busbar) integrated distribution board, and the total amperage is increased to 75A or 100A (a qualified electrical appliance contractor needs to be entrusted to Taipower to review the additional power capacity).
Residential electricity self-test and regular inspection checklist
- Appearance and temperature of the socket: Touch the outer cover of the commonly used socket lightly with the back of your hand. If it feels lukewarm or if you find that the plastic socket is yellowed and charred, or the plug is loose and shaking after being plugged in, it means that the internal copper plate clamping force is exhausted or the contact resistance is too high, and you should immediately cut off the power and replace it.
- Regular testing of leakage circuit breakers (ELCB): For leakage circuit breakers in humid places such as balconies, bathrooms, and kitchen sinks, regulations require that the "TEST button" on the switch be pressed once every 1 to 3 months to confirm that it can automatically trip and cut off the power supply instantly.
- Serial connection and overloading of extension cords are strictly prohibited: Extension cords should be purchased with 2.0mm thick wire diameter products that have CNS certification and automatic overload power-off protection. Do not share the same extension cord with high energy-consuming appliances to ensure zero hidden danger to life and property at home.