The main breaker is the switch in the panel with the highest rated current, usually at the top or on the far left. Spend one session testing each switch and putting up large labels, so that in an emergency an elderly family member only has to remember “turn off the biggest one” (關最大那顆). Panel locations and layouts differ from home to home, so this article says “usually” and shows you how to confirm by checking amperage and testing. It only covers identifying and labeling an existing panel. It does not cover opening the inner cover, wiring or replacing components, which is work for a qualified electrician.
Find Your Main Breaker and Label the Panel for Seniors

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
Know your panel: main breaker, branch breakers and the earth-leakage breaker
When you open the outer door of the panel, you will usually see a row of toggle-style switches. As long as you do not remove the inner cover, the printed text on the switch faces, the toggle positions and the test buttons are all things a homeowner can safely read and check.
How to tell the main breaker by amperage and position
- Check the amperage: The rated current is printed on the face. The main breaker is usually the largest number in the whole box, and the actual value depends on your power contract and the design.
- Check the position: It is usually at the top or on the far left, and its toggle is often wider and larger.
- Check whether it is separate: In some homes the main breaker sits in a separate small box or next to the electricity meter.
- Ask an electrician if you are unsure: If two large switches show similar numbers, do not go by memory.
For the differences between the types of switches, see this guide to NFB, ELCB and RCBO breakers and wiring in the panel. For how amperage relates to wire size, use the wire size and breaker amperage calculator.
The test button on the earth-leakage breaker
An earth-leakage breaker usually has a small button marked “TEST” or “T”, and the switch should trip when you press it. Before pressing, make sure nothing that cannot lose power suddenly, such as a computer or medical equipment, is running. Push the toggle back afterward. If it does not trip when you press the button, contact an electrician to inspect it.
Find out what each switch controls
Two-person testing steps
- First print the blank chart below, get a pen and your phone, pick a time during the day, and tell your family the power will be off briefly.
- One person stands in front of the panel and moves only the toggles visible inside the outer door by hand, without touching any metal parts and without opening the inner cover.
- Turn off one switch at a time while the other person walks through the rooms, checking which lights, outlets and air conditioners have no power, and writing it down.
- After recording, push that switch back to ON, wait one minute, then test the next one. Never switch off several at once.
- Test the main breaker last, and only switch it off after every device has been taken care of.
If a toggle will not go back, trips again right after you push it back, or you smell burning, stop and call an electrician.
What to deal with before cutting power
- Refrigerator: A brief outage is usually fine, but keep it as short as possible and test its circuit last.
- Medical equipment (such as an oxygen machine): First confirm there is a backup power source or an alternative. If you are not sure, ask medical staff or the equipment supplier, and never cut power while it is in use.
- Computers and network equipment: Save your files and shut down first to avoid losing data.
How to label so seniors can read it
Large text, colors and room names
- Next to the main breaker, put thick, black, large text reading 總開關 (“main breaker”) with a red sticker, and state the actual toggle direction, such as “toward OFF = off” (往 OFF 撥=關).
- Label branch breakers with room names, such as 客廳 (“living room”) and 廚房 (“kitchen”), rather than just 迴路 3 (“circuit 3”).
- Use no more than two or three colors, for example red for the main breaker and yellow for the refrigerator and medical equipment circuits. Always add words in addition to color.
- Put labels on the outside of the door or on the panel edge directly below the switch. Do not cover the printed rated-current text, and do not stick anything where you would need to open the inner cover to reach it.
A circuit chart on the inside of the door
Stick a chart on the inside of the outer door and send a photo of it to family members by phone. Here is a blank template:
| Switch no. | Amps | Area supplied | Notes |
|---|---|---|---|
| Main breaker | __ A | Whole home | The largest one; turn this off in an emergency |
| 1 | __ A | ________ | ________ |
| 2 | __ A | ________ | Note it if it feeds a refrigerator or medical equipment |
When to switch off the main breaker right away
The principle is personal safety first: if smoke or standing water is already around the panel, or you would have to stand on a wet floor to reach it, do not go near it.
| Situation | What to do first | What not to do |
|---|---|---|
| Burning smell, smoke, or a hot outlet | Get people away first. If the position is safe, switch off the main breaker, and call 119 if needed | Do not use water on an electrical fire |
| Before flooding | Move people to higher ground and switch off the main breaker before the water gets close | Do not operate the panel when your feet are already in water |
| After flooding | Confirm the area around the panel is dry, then ask an electrician to inspect | Do not restore power yourself |
| Gas smell after an earthquake | Open the windows and evacuate, then call 119 or the gas company from outside | Do not switch any appliance on or off, and do not touch the main breaker |
Burning smell or smoke
If the burning smell comes from a single outlet or appliance, you can unplug it, as long as you do not touch the hot part. If it comes from inside the wall or the panel, or there is smoke, first get people out, then switch off the main breaker and call 119.
Before and after flooding
Before flooding, switch off the main breaker while the water has not yet reached the panel. After flooding, the wiring may be damp, so first read the panel safety check before restoring power after a flood and have an electrician confirm.
Do not touch any switch if you smell gas after an earthquake
When there is a gas smell, flipping any appliance switch or the main breaker can cause a spark. So do not touch lights, exhaust fans or the panel. Open the windows, evacuate, and report it from outside. Be sure to tell elderly family members that the instinct of “cut the power after an earthquake” (地震先關電) is exactly the opposite of what to do when there is a gas smell.
When the panel location or its age calls for an electrician
| Homeowner can do | Qualified electrician needed |
|---|---|
| Identify the main breaker, put on labels, fill in the chart, press the test button | Open the inner cover, inspect wiring, replace switches, move the panel |
Panel blocked by furniture or mounted too high
Leave room in front of the panel to stand and to open the door fully. If a cabinet is blocking it, clear it away first. If it is mounted so high that an elderly person would have to stand on a chair to reach it, ask an electrician to assess an improvement, and see this assessment of electrical upgrades for old homes.
Hot switches, odd noises, or no earth-leakage breaker
A switch that is clearly hot, a humming sound, a loose toggle or frequent tripping all call for an electrician to inspect. See this check for panel breaker humming and arcing for details. If the box has no earth-leakage breaker, we also recommend asking an electrician to assess adding one.
FAQ
Which one in the panel is the main breaker?
It is usually the one with the largest rated current, located at the top or on the far left. Homes differ, so confirm it by amperage and by testing with two people.
Will switching off the main breaker damage appliances?
Switching off the main breaker is a normal way to cut power, and the outage itself generally does not damage appliances, though an unsaved computer file may be lost. When restoring power, switch off the large appliances first, then push the main breaker back. You can check the steps with the power outage assistant.
What if an elderly person cannot operate the panel?
Teach just one thing: “turn off the biggest one” (關最大那顆). Put large-print instructions next to the box, have them do it once in person, and review it regularly. If they cannot reach it or have limited mobility, ask an electrician to assess the panel location.
Can I push the breaker back myself after a trip?
First unplug the appliances used most recently and confirm there is no burning smell. Then push the toggle to OFF first and back to ON. If it trips again right away, do not keep retrying. If an earth-leakage breaker tripped, or there has been flooding or a burning smell, have an electrician deal with it.
Sources
- Laws and Regulations Database of Taiwan: Regulations for Installation of Consumer Electrical Equipment (verified 2026-11-11): general rules on distribution boards, branch circuit labeling and earth-leakage breakers.
- Taiwan Power Company: electrical safety and outage response guide (verified 2026-11-07): electrical safety during disasters and notes on restoring power.
- Ministry of the Interior National Fire Agency: home electrical safety and electrical fire prevention advice (verified 2026-11-07): home electrical safety and notes for after an earthquake.
Related reading: Burnt Panel After DIY Wiring: Steps and Repair Scope