As living standards rise, many owners renovating an older home or fitting out a new one consider installing a “whole-home filtration system” and a “whole-home central water softener” on the main inlet pipe at the service balcony or rooftop. They hope to ease dry skin after bathing and reduce white scale on shower heads, thermostatic faucets and glass shower doors. However, tap-water quality across Taiwan differs markedly with the water source (the share of reservoir water, infiltration water or groundwater) and the supply area. According to the water hardness classification standards of the World Health Organization (WHO) and Taiwan's water utilities, total hardness of 0 - 60 mg/L (as calcium carbonate, CaCO₃) counts as “soft water”. In the Feitsui Reservoir supply area in northern Taiwan (the main part of Greater Taipei), total hardness is mostly below 60 mg/L (measured even below 40 mg/L at most water treatment plants), so the water quality is very good. Some supply areas in Taoyuan and Hsinchu are mostly moderately soft to slightly hard (depending on the source of each treatment plant, and not necessarily all above 120 mg/L), while high-hardness water (commonly 120 to 250 mg/L or more) is concentrated mainly in southern Taiwan (especially some supply areas in Kaohsiung and Pingtung). Before spending from tens of thousands to over one hundred thousand NT dollars on a whole-home softener, owners are advised to check the latest water quality test report for their own treatment plant on the website of Taiwan Water Corporation or the Taipei Water Department.
Taiwan Whole-Home Softener vs RO: Bypass Valves, Circuits

This article is compiled from publicly available online sources for general reference only; readers should independently verify and judge its accuracy, and it is not legal, tax, medical or engineering advice. Rules, fees and subsidies change; check the latest notice from the responsible authority before acting. For electrical, gas, structural or health risks, consult a qualified professional.
This is the English edition of a Chinese article, adapted with AI assistance and checked against the original. Where the two differ, the Chinese version and the official sources it cites prevail.
Whole-Home Filtration, Whole-Home Softening and Under-Sink Drinking Systems: Functions and Cost Reference
Many consumers confuse the functions of “water purification” and “water softening”, and some even assume that after installing a whole-home softener they can drink straight from the tap. When planning whole-house water treatment, build the right understanding of a three-layer division of work: whole-home physical / activated-carbon filtration → whole-home ion-exchange softening → under-sink RO drinking-water purification.
| Equipment type | Main function and design limits | Reference price for the unit with basic installation (NT$) | Reference annual consumables cost (NT$) | Plumbing, electrical and space points to confirm |
|---|---|---|---|---|
| Whole-home filter (such as a jumbo-housing single-stage / double-stage unit or an automatic backwash pre-filter) |
Depending on the PP cotton, pleated screen or compressed activated-carbon cartridge fitted, it intercepts silt and suspended rust in the water and adsorbs some residual chlorine and odors (it cannot reduce water hardness or remove scale) | 15,000 - 38,000 | 3,500 - 7,000 (cartridges replaced every 6–12 months depending on the household's actual water use and cartridge specification) | The main inlet pipe must be cut and there must be wall-mounted or floor-standing space; ordinary filter housings need no power or drainage (automatic backwash models need a reserved 110V socket and a drain outlet) |
| Whole-home central water softener (cation-exchange resin system) |
Food-grade cation-exchange resin swaps sodium ions for the calcium and magnesium ions in the water, markedly reducing scale formation, making bathing feel smoother and extending water heater life (important health reminder: a whole-home softener cannot filter bacteria or viruses or disinfect; softened water is still not drinking water and must not be drunk directly, and because the sodium content rises slightly, it is not recommended for people with hypertension or kidney disease to drink it directly over the long term) | 48,000 - 110,000 | 3,000 - 6,000 (water-softener salt tablets of high purity must be added regularly; the internal resin life depends on local water hardness and regeneration frequency, and is usually replaced once every few years) | A 110V power socket, a nearby floor drain (to discharge the brine from resin regeneration backwash), enough floor space and a sun-and-rain cover (to keep direct sunlight from aging the resin tank body) must be provided |
| Under-sink RO reverse-osmosis drinking-water unit | A high-precision RO semipermeable membrane filters out heavy metals, bacteria and viruses and removes the vast majority of dissolved ions (including the sodium ions swapped in by the softener), producing pure drinking water that meets raw-drinking standards | 22,000 - 55,000 | 4,000 - 8,500 (each pre-filter cartridge and the RO membrane are replaced regularly) | Inside the under-sink cabinet, a cold-water tee fitting and a dedicated drain hole must be reserved; for an instant-heating / heating dual-temperature dispenser, a separate dedicated power socket must be provided according to its rated power |
*(Financial planning note: building a whole-home filtration and central softening setup together with its piping often costs NT$80,000 to NT$150,000 or more. Some banks and large appliance retailers offer “green consumer loans” or zero-interest credit-card installment plans for top-grade energy-saving appliances or home water purification equipment, and owners can consider them according to their own cash flow.)*
3 Practical Plumbing Principles for Whole-Home Water Treatment Piping and Water Pressure Assessment
- Mandatory physical “three-valve by-pass piping”: At the inlet and outlet of the whole-home filter and softener, have a 水電師傅 (plumber/electrician) fit three ball valves in stainless-steel press-fit pipe or drinking-water-grade heavy-wall PVC: an inlet isolation valve, an outlet isolation valve and a central by-pass valve. During normal filtering, open the inlet and outlet valves and close the central by-pass valve. When changing cartridges, servicing the softener, or if a filter housing ruptures and leaks because of water hammer, the owner only needs to close the inlet and outlet valves and open the by-pass valve to restore normal tap water to the whole home within 10 seconds, completely avoiding a situation where the whole home has no water.
- Distinguish “static pressure” from “dynamic pressure”, and the booster pump ban in multi-unit housing: Water passing through several precision cartridges and the softener resin tank inevitably suffers some pressure loss (pressure drop; the actual size of the drop must be judged from the simultaneous flow rate and the manufacturer's pressure-loss curve for the equipment). If the home's original water pressure is low (for example on the top floor or the floor below it, with insufficient height difference from the rooftop water tank), installing whole-home water treatment equipment may weaken bathroom water pressure and may even fall short of the minimum start-up water pressure and flow of outdoor-type or indoor forced-exhaust thermostatic water heaters. Whether a booster pump should be installed before or after the treatment equipment, and its pressure setting (which must be strictly below the maximum working pressure marked on the filter housing and softener tank, a common limit being about 4 to 6 kgf/cm²), should all be designed by professional plumbing and electrical personnel from on-site pressure gauge readings and the equipment's pressure rating. Never blindly raise the booster pump pressure, which can burst the filter housing.
* Warning on booster pump rules in multi-unit housing: Because of low-frequency resonance noise when running at night and to avoid upsetting the water pressure balance of the building's shared water supply main, many condominium management committees (管委會) have expressly prohibited residents from installing booster pumps on their own unit's piping in the community rules. If a resident installs one in violation, under Article 49 of the Condominium Administration Act the management committee may report to the competent authority for a fine of NT$40,000 to NT$200,000 and a compulsory order to remove it and restore the original condition. Before buying the equipment, always confirm the community rules with the management committee. - Direct the softener's regeneration wastewater properly into a drain pipe: According to its set water-use volume (usually once every 3 to 7 days in the early hours), a whole-home softener automatically runs a “salt-draw regeneration backwash” cycle, discharging each time roughly several tens of liters of backwash wastewater with a high salt concentration. During piping, the softener's drain hose should be firmly secured and connected into the balcony floor drain pipe, to keep high-salinity wastewater from spreading over the balcony floor tiles and around the metal base of the washing machine for long periods, which would make the washing machine casing rust and corrode early.
Reference Planning of Dedicated Circuits for High-Power Kitchen and Bathroom Appliances (Not to Be Used Directly as Construction Design)
Modern kitchens and bathrooms often have several high-power European or Japanese appliances at once, and if they are not inventoried before renovation, the power trips easily (tripped breaker / power trip) after move-in. The table below is only a reference for owners and plumbing and electrical contractors to take stock of requirements when communicating, and is not a general construction design table. The actual conductor size, insulation heat rating, installation method and the specifications of the no-fuse breaker (NFB, 無熔絲開關) and earth-leakage circuit breaker (ELCB, 漏電斷路器) must be calculated and selected by a qualified electrical installation contractor according to each appliance's nameplate rated current, the manufacturer's installation manual and the current Regulations for Installation of Customer Electrical Equipment (用戶用電設備裝置規則):
| High-power appliance | Common rated power and voltage range | Plumbing and electrical planning and safety points to confirm |
|---|---|---|
| Built-in two- or three-zone IH induction cooktop | Commonly about 3,500 W - 7,400 W (mostly 220V single-phase supply) | It needs its own dedicated circuit, with a large-gauge conductor (such as 5.5 mm² or 8 mm²) and a dedicated breaker calculated from the nameplate maximum current and the cable length, and it must not share the circuit with other appliances; some plug-less models must be connected directly to terminals by a professional |
| Built-in / freestanding dishwasher | Depending on European-standard (220V) or American/Japanese-standard (110V), commonly about 1,500 W - 2,400 W | Before wiring during renovation, you must first choose the dishwasher model and confirm its voltage (110V or 220V) and plug type (such as European-standard round pins or a T-type plug), provide a dedicated circuit and fit leakage protection as required by the rules; the socket should be placed in the adjacent cabinet, not directly behind the machine where it would reduce the built-in depth |
| Under-sink instant-heating / storage-heating dual-temperature dispenser | Commonly about 1,200 W - 2,200 W (110V or 220V) | It is a high-power heating load, so a separate dedicated circuit is recommended, rather than sharing the same set of kitchen countertop sockets with a microwave, a steam oven or an air fryer |
| Bathroom four-in-one heating, ventilation and drying unit (bathroom heater) | Commonly about 1,350 W - 2,650 W (110V or 220V) | Provide a dedicated line according to the nameplate voltage, and fit an earth-leakage circuit breaker (ELCB) of suitable rating in line with the electrical safety rules for high-humidity bathrooms; during installation, leave enough power cable length for wiring the unit inside the ceiling |
---
Related reading: Whole House Water Filtration and Bypass Valve Setup Guide · Whole House Water Softener Energy Savings and Lifespan ROI